Effect Of Finite Element Analysis On Knee Implant Materials Under Static Conditions

Autores/as

  • Shashishekar C Associate Professor, Department of Mechanical Engineering, Siddaganga Institute of Technology, Tumakuru Autor/a
  • Sanjay S.J Research Scholar, Department of Mechanical Engineering, Siddaganga Institute of Technology, Tumakuru Autor/a
  • Veereshkumar Ambiger Under Graduate Student, Department of Mechanical Engineering, Basaveshwar Engineering College, Bagalkot, Karnataka, India Autor/a
  • Nagappa.V Sankannavar Under Graduate Student, Department of Mechanical Engineering, Basaveshwar Engineering College, Bagalkot, Karnataka, India Autor/a
  • Veeranna R. Kattimani Associate professor, Department of Chemistry, Basaveshwar Engineering College, Bagalkot, Karnataka, India Autor/a

DOI:

https://doi.org/10.48047/wrrgfw21

Palabras clave:

Finite Element Analysis, Knee Implant, Tibial Component, Static Conditions, Stress Analysis, Implant Materials, Biomechanics, Mechanical Properties, Implant Design Optimization, Biomedical Engineering.

Resumen

 Finite Element Analysis (FEA) is a powerful computational tool used to study the behaviour of materials and structures under various conditions. This study specifically focuses on conducting static analysis of knee implant materials to evaluate their mechanical performance and suitability for biomedical applications.The research involves modelling knee implant components using FEA to analysed stress distribution, deformation, and overall structural integrity under static loading conditions.

Descargas

Los datos de descarga aún no están disponibles.

Referencias

Steve A Maas, Benjamin J Ellis , Gerard A Ateshian , Jeffrey A Weiss ,FEBio: Finite Elements for Biomechanics, Journal of Biomechanical Engineering, 2012,Volume:8,Issue:134(1),P. 011005-1- 01100510.

M.A.Lafortune , P.R.Cavanagh, H.J.Sommer, A.Kalenak,Three-dimensional kinematics of the human knee during walking, , Journal of Biomechanical

Engineering, 1992 Volume:25, Issue: (4), P.34757.B. Morrison, The Mechanics of The Knee Joint in Relation to Normal Walking, Journal of

Biomechanics,1970,Volume. 3, Issue:1, P. 51-61.